Energy Storage System   > Solar Inverter >

  • 29.9–50kW Three-Phase High Voltage Hybrid Energy Storage Inverter

29.9–50kW Three-Phase High Voltage Hybrid Energy Storage Inverter

  • Solis S6-EH3P
  • 29.9–50kW three-phase high-voltage hybrid inverter for C&I energy storage, supporting solar PV, 150–800V battery, grid and diesel generator integration with dual battery ports, multiple MPPTs and <10ms backup switching.
  • INQUIRY

Product Overview

The 29.9–50kW Three-Phase High Voltage Hybrid Energy Storage Inverter is designed for commercial and industrial solar-storage and hybrid power applications.

The series supports integrated operation of Solar PV, high-voltage battery storage, utility grid and diesel generator, providing flexible power management for C&I facilities, backup power systems, microgrids and weak-grid projects.

Available in 29.9kW, 30kW, 40kW and 50kW models, the inverter supports up to 2× PV oversizing, dual battery ports, generator input, AC/DC coupling, fast on/off-grid transfer and multi-unit parallel operation.

With battery voltage from 150V to 800V, multiple MPPT inputs and intelligent energy management, the system provides a flexible platform for both new ESS projects and retrofit applications.


Key Features

  • 29.9 / 30 / 40 / 50kW rated output options

  • Three-phase high-voltage hybrid energy storage inverter

  • Supports PV + Battery + Grid + Diesel Generator

  • Up to 2× rated PV array capacity

  • Battery voltage range: 150–800V

  • Dual independent battery ports

  • Maximum battery charging current up to 140A

  • Multiple MPPT inputs

  • Compatible with high-power PV modules

  • Supports DC and AC coupling

  • Generator input support

  • 100% backup power capability

  • 160% off-grid overload for 2 seconds

  • On-grid / off-grid switching <10ms

  • Battery reserve management

  • Intelligent load prioritization

  • Multi-unit parallel operation up to 500kW

  • 7-inch industrial-grade display

  • IP66 outdoor protection

  • Intelligent fan cooling

  • CAN / RS485 / Ethernet communication


Model Range

ModelRated OutputRecommended Max. PV ArrayMax. Usable PV Input
29.9K29.9kW59.8kW59.8kW
30K30kW60kW60kW
40K40kW80kW80kW
50K50kW100kW96kW

Technical Specifications

PV Input

ParameterSpecification
Max. Input Voltage1000V
Rated PV Voltage600V
Start-up Voltage180V
MPPT Voltage Range150–850V
Max. MPPT Input CurrentUp to 40A per MPPT
Max. Short-Circuit CurrentUp to 60A per MPPT
MPPT ConfigurationMultiple MPPTs
Max. Input StringsUp to 8 strings

The system supports flexible PV array design and high-power PV modules, making it suitable for modern commercial solar projects.


Battery Input

ParameterSpecification
Battery TypeLi-ion
Battery Voltage Range150–800V
Number of Battery Ports2
Max. Total Charge / Discharge CurrentUp to 140A
BMS CommunicationCAN / RS485

Maximum Charge / Discharge Power

ModelMax. Battery Charge / Discharge Power
29.9K32.1kW
30K33kW
40K44kW
50K55kW

The two independent battery ports provide additional flexibility for battery configuration and future capacity expansion.


AC Grid Output

ParameterSpecification
Rated Output Power29.9 / 30 / 40 / 50kW
Rated Grid Voltage3/N/PE, 220/380V or 230/400V
Rated Frequency50 / 60Hz
Power Factor>0.99
Adjustable PF Range0.8 Leading – 0.8 Lagging
THDi<3%

Rated Output Current

Model380V / 400V
29.9K45.4A / 43.2A
30K45.6A / 43.3A
40K60.8A / 57.7A
50K76A / 72.2A

Grid AC Input

The inverter supports bidirectional grid interaction, allowing the system to charge the battery from the grid when required and discharge energy according to the configured energy-management strategy.

The AC passthrough capability is suitable for systems requiring both grid supply and backup-load operation.


Diesel Generator Input

One of the main advantages of this series is its integrated diesel generator interface.

The inverter can coordinate:

Diesel Generator + Battery + Solar PV + Grid

Generator input can be used for:

  • Backup power

  • Battery charging

  • Hybrid off-grid operation

  • Weak-grid support

  • Remote sites

  • Peak load support

The system supports generator input over a relatively wide operating range, helping reduce unnecessary generator oversizing.

For your Linkworld Power positioning, this is one of the features I would emphasize most.


Backup / Off-Grid Output

The inverter provides backup power for critical loads when grid power is unavailable.

Key Backup Features

  • Fast transfer <10ms

  • Rated backup power up to 50kW

  • Up to 160% rated power for 2 seconds

  • Three-phase output

  • Intelligent critical-load prioritization

  • Battery reserve management

  • On-grid and off-grid operation

This makes the series suitable for facilities where uninterrupted power supply is important.


Efficiency

ParameterSpecification
Max. Efficiency97.8%
European Efficiency97.4%
PV-to-Battery Max. Efficiency98.5%
Battery-to-AC Max. Efficiency97.5%

Hybrid Power Integration

A typical system can combine:

Solar PV

Provides renewable power to local loads and charges the battery.

Battery Energy Storage

Stores surplus energy and provides backup or peak-shaving power.

Grid

Provides supplemental power or receives excess energy according to system configuration.

Diesel Generator

Provides backup generation and can support battery charging when required.

Hybrid Inverter

Coordinates energy conversion and distribution between all energy sources.

A typical configuration is:

Solar PV → Hybrid Inverter ← Battery ESS

Grid ↔ Hybrid Inverter → Loads

Diesel Generator → Hybrid Inverter → Loads / Battery

This architecture is particularly suitable for Solar + BESS + Generator + Grid hybrid projects.


Smart Energy Management

The inverter supports intelligent system control for applications such as:

  • Solar self-consumption

  • Peak shaving

  • Battery reserve management

  • Time-of-use energy management

  • Critical load prioritization

  • Generator-assisted charging

  • Backup power

  • Microgrid operation

Remote monitoring and energy-management functions can also be supported through the manufacturer's monitoring platform.


Parallel System Expansion

Multiple units can be connected in parallel for larger projects.

The series supports system expansion up to approximately:

500kW

For larger parallel systems, additional system switching/control equipment may be required according to the project configuration.

This means you can use the same inverter family for projects ranging from smaller C&I installations to larger commercial energy-storage systems.


Protection Functions

The inverter includes multiple protection functions, including:

  • Anti-Islanding Protection

  • Output Over-Current Protection

  • Short-Circuit Protection

  • DC Reverse Polarity Protection

  • Integrated DC Switch

  • Surge Protection

  • Battery Protection

  • Grid Monitoring

  • Optional AFCI Protection


General Specifications

ParameterSpecification
Dimensions530 × 880 × 290 mm
WeightApprox. 73kg
TopologyTransformerless
Protection RatingIP66
CoolingIntelligent Fan Cooling
Operating Temperature-25°C to +60°C
Relative Humidity0–100%
Max. Operating Altitude4000m
Night Self-Consumption<35W

Communication & Monitoring

Available communication interfaces include:

  • CAN

  • RS485

  • Ethernet

  • Bluetooth + APP

  • Optional Wi-Fi

  • Optional Cellular Communication

  • Optional LAN

A 7-inch LCD display provides convenient local monitoring and system operation.


Applications

Suitable for:

Commercial & Industrial Energy Storage

Solar + Battery Systems

Generator + Battery Hybrid Power

Solar + BESS + Generator + Grid

Peak Shaving & Load Shifting

Backup Power Systems

Microgrids

Factories & Industrial Facilities

Commercial Buildings

Telecom & Remote Sites

Weak-Grid Applications

Off-Grid Energy Systems


Why Choose This Hybrid Inverter?

Flexible Hybrid Integration

Supports PV, battery storage, grid and diesel generator within one system architecture.

High PV Utilization

Up to 2× PV array sizing allows greater renewable-energy utilization.

Flexible Battery Expansion

Two independent battery ports simplify battery configuration and future expansion.

Reliable Backup

Less than 10ms transfer and temporary overload capability help maintain critical loads during outages.

Generator Compatibility

Generator integration is particularly useful for remote, weak-grid and hybrid power applications.

Scalable Architecture

Parallel operation allows the system to expand from individual C&I projects toward larger installations.