The 29.9–50kW Three-Phase High Voltage Hybrid Energy Storage Inverter is designed for commercial and industrial solar-storage and hybrid power applications.
The series supports integrated operation of Solar PV, high-voltage battery storage, utility grid and diesel generator, providing flexible power management for C&I facilities, backup power systems, microgrids and weak-grid projects.
Available in 29.9kW, 30kW, 40kW and 50kW models, the inverter supports up to 2× PV oversizing, dual battery ports, generator input, AC/DC coupling, fast on/off-grid transfer and multi-unit parallel operation.
With battery voltage from 150V to 800V, multiple MPPT inputs and intelligent energy management, the system provides a flexible platform for both new ESS projects and retrofit applications.
29.9 / 30 / 40 / 50kW rated output options
Three-phase high-voltage hybrid energy storage inverter
Supports PV + Battery + Grid + Diesel Generator
Up to 2× rated PV array capacity
Battery voltage range: 150–800V
Dual independent battery ports
Maximum battery charging current up to 140A
Multiple MPPT inputs
Compatible with high-power PV modules
Supports DC and AC coupling
Generator input support
100% backup power capability
160% off-grid overload for 2 seconds
On-grid / off-grid switching <10ms
Battery reserve management
Intelligent load prioritization
Multi-unit parallel operation up to 500kW
7-inch industrial-grade display
IP66 outdoor protection
Intelligent fan cooling
CAN / RS485 / Ethernet communication
| Model | Rated Output | Recommended Max. PV Array | Max. Usable PV Input |
|---|---|---|---|
| 29.9K | 29.9kW | 59.8kW | 59.8kW |
| 30K | 30kW | 60kW | 60kW |
| 40K | 40kW | 80kW | 80kW |
| 50K | 50kW | 100kW | 96kW |
| Parameter | Specification |
|---|---|
| Max. Input Voltage | 1000V |
| Rated PV Voltage | 600V |
| Start-up Voltage | 180V |
| MPPT Voltage Range | 150–850V |
| Max. MPPT Input Current | Up to 40A per MPPT |
| Max. Short-Circuit Current | Up to 60A per MPPT |
| MPPT Configuration | Multiple MPPTs |
| Max. Input Strings | Up to 8 strings |
The system supports flexible PV array design and high-power PV modules, making it suitable for modern commercial solar projects.
| Parameter | Specification |
|---|---|
| Battery Type | Li-ion |
| Battery Voltage Range | 150–800V |
| Number of Battery Ports | 2 |
| Max. Total Charge / Discharge Current | Up to 140A |
| BMS Communication | CAN / RS485 |
| Model | Max. Battery Charge / Discharge Power |
|---|---|
| 29.9K | 32.1kW |
| 30K | 33kW |
| 40K | 44kW |
| 50K | 55kW |
The two independent battery ports provide additional flexibility for battery configuration and future capacity expansion.
| Parameter | Specification |
|---|---|
| Rated Output Power | 29.9 / 30 / 40 / 50kW |
| Rated Grid Voltage | 3/N/PE, 220/380V or 230/400V |
| Rated Frequency | 50 / 60Hz |
| Power Factor | >0.99 |
| Adjustable PF Range | 0.8 Leading – 0.8 Lagging |
| THDi | <3% |
| Model | 380V / 400V |
|---|---|
| 29.9K | 45.4A / 43.2A |
| 30K | 45.6A / 43.3A |
| 40K | 60.8A / 57.7A |
| 50K | 76A / 72.2A |
The inverter supports bidirectional grid interaction, allowing the system to charge the battery from the grid when required and discharge energy according to the configured energy-management strategy.
The AC passthrough capability is suitable for systems requiring both grid supply and backup-load operation.
One of the main advantages of this series is its integrated diesel generator interface.
The inverter can coordinate:
Diesel Generator + Battery + Solar PV + Grid
Generator input can be used for:
Backup power
Battery charging
Hybrid off-grid operation
Weak-grid support
Remote sites
Peak load support
The system supports generator input over a relatively wide operating range, helping reduce unnecessary generator oversizing.
For your Linkworld Power positioning, this is one of the features I would emphasize most.
The inverter provides backup power for critical loads when grid power is unavailable.
Fast transfer <10ms
Rated backup power up to 50kW
Up to 160% rated power for 2 seconds
Three-phase output
Intelligent critical-load prioritization
Battery reserve management
On-grid and off-grid operation
This makes the series suitable for facilities where uninterrupted power supply is important.
| Parameter | Specification |
|---|---|
| Max. Efficiency | 97.8% |
| European Efficiency | 97.4% |
| PV-to-Battery Max. Efficiency | 98.5% |
| Battery-to-AC Max. Efficiency | 97.5% |
A typical system can combine:
Provides renewable power to local loads and charges the battery.
Stores surplus energy and provides backup or peak-shaving power.
Provides supplemental power or receives excess energy according to system configuration.
Provides backup generation and can support battery charging when required.
Coordinates energy conversion and distribution between all energy sources.
A typical configuration is:
Solar PV → Hybrid Inverter ← Battery ESS
Grid ↔ Hybrid Inverter → Loads
Diesel Generator → Hybrid Inverter → Loads / Battery
This architecture is particularly suitable for Solar + BESS + Generator + Grid hybrid projects.
The inverter supports intelligent system control for applications such as:
Solar self-consumption
Peak shaving
Battery reserve management
Time-of-use energy management
Critical load prioritization
Generator-assisted charging
Backup power
Microgrid operation
Remote monitoring and energy-management functions can also be supported through the manufacturer's monitoring platform.
Multiple units can be connected in parallel for larger projects.
The series supports system expansion up to approximately:
500kW
For larger parallel systems, additional system switching/control equipment may be required according to the project configuration.
This means you can use the same inverter family for projects ranging from smaller C&I installations to larger commercial energy-storage systems.
The inverter includes multiple protection functions, including:
Anti-Islanding Protection
Output Over-Current Protection
Short-Circuit Protection
DC Reverse Polarity Protection
Integrated DC Switch
Surge Protection
Battery Protection
Grid Monitoring
Optional AFCI Protection
| Parameter | Specification |
|---|---|
| Dimensions | 530 × 880 × 290 mm |
| Weight | Approx. 73kg |
| Topology | Transformerless |
| Protection Rating | IP66 |
| Cooling | Intelligent Fan Cooling |
| Operating Temperature | -25°C to +60°C |
| Relative Humidity | 0–100% |
| Max. Operating Altitude | 4000m |
| Night Self-Consumption | <35W |
Available communication interfaces include:
CAN
RS485
Ethernet
Bluetooth + APP
Optional Wi-Fi
Optional Cellular Communication
Optional LAN
A 7-inch LCD display provides convenient local monitoring and system operation.
Suitable for:
Commercial & Industrial Energy Storage
Solar + Battery Systems
Generator + Battery Hybrid Power
Solar + BESS + Generator + Grid
Peak Shaving & Load Shifting
Backup Power Systems
Microgrids
Factories & Industrial Facilities
Commercial Buildings
Telecom & Remote Sites
Weak-Grid Applications
Off-Grid Energy Systems
Supports PV, battery storage, grid and diesel generator within one system architecture.
Up to 2× PV array sizing allows greater renewable-energy utilization.
Two independent battery ports simplify battery configuration and future expansion.
Less than 10ms transfer and temporary overload capability help maintain critical loads during outages.
Generator integration is particularly useful for remote, weak-grid and hybrid power applications.
Parallel operation allows the system to expand from individual C&I projects toward larger installations.